MPU-M
These DiBO industrial stationary high-pressure units offer you unlimited possibilities for diff erent cleaning applications for
professional and industrial use. The pump units can be connected to pipes with a number of user connection points. The pumps are automatically switched on or off depending on the number of users, so the required capacity is always guaranteed.
As standard the MPU-M is suitable for a water supply temperature up to 40 °C and has a maximum power connection of up to 100A. The high-pressure unit is also optionally available with HT pumps that are suitable for a water supply temperature up to 75 °C (peaks to 85 °C). With a temperature of 40 °C or more, always use a prepressure pump supplying an inlet pressure of at least 3 bar.
The general options are summed up below, but many other combinations and capacities are also possible. You always start
by choosing the basic confi guration depending on the number of required pump units and the type of pressure regulator (1.249.1xx). You can then select the type of pump units depending on the required pressure and the fl ow rate. Note that you must select the same number of pump units depending on your fi rst choice (1.294.1xx). If you want to regulate consumption even more precisely (to max ½ of the fl ow rate of 1 pump unit), and save energy, choose the frequency regulator option (maximum of 1 per machine).
Contact our sales department to discuss the confi guration options and the most suitable setup for your specifi c use. Together
with our R&D department they will look for the best solution to your needs!
Note: For pump units above 7.5 kW a soft starter on each pump unit is strongly
Specifications
Product
Robust polished stainless steel frame, provided with a 300 l float tank
With an automatic start/stop system with delay by a flow rate and pressure sensor
Variations:
- MPU-M motor/pump unit 5,5 kW - with an operating pressure from min. 70 up to max. 130 bar
- MPU-M motor/pump unit 7,5 kW - with an operating pressure from min. 55 up to max. 170 bar
- MPU-M motor/pump unit 11,0 kW - with an operating pressure from min. 80 up to max. 210 bar
- MPU-M motor/pump unit 15,0 kW - with an operating pressure from min. 80 up to max. 275 bar
Technical
Multiple-section pump unit with different choices for engine/pump combinations
As a standard suitable for both cold and hot water supply (up to 40°C) As an option, the high pressure unit is also available with HT pumps, which are suitable for a water supply up to 75°C (peaks up to 85°C). At a temperature of 40°C or more, always use a pump that provides an inlet pressure of at least 3 bar.
Electrical box
Solenoid filling valve
Pressure gauge
Thermal engine protection
Protected against breaks in the pipes and overpressure
Dry-run and temperature security system on the float chamber
Very economic
Equipped with mechanical pressure regulator or electro-pneumatic (option)
Automatic adjustment to variable off-take
Standard motors: direct-in - optionally configurable with softstarter and/or frequency inverter
Variations
SKU | Description | bar | l/h | ° C | kW | rpm | l | mm |
---|---|---|---|---|---|---|---|---|
1.149.xxx | Motor/pump unit - 5,5 kW | 130 | 2400 | 40 | 5,50 | 1500 | 1970x1040x1170 | |
1.149.xxx | Motor/pump unit - 7,5 kW | 170 | 4200 | 40 | 7,50 | 1500 | 1970x1040x1170 | |
1.149.xxx | Motor/pump unit - 11 kW | 210 | 2400 | 40 | 11,00 | 1500 | 1970x1040x1170 | |
1.149.xxx | Motor/pump unit - 15 kW | 275 | 4200 | 40 | 15,00 | 1500 | 1970x1040x1170 | |
1.249.100 | 2-D MPU-M with mechanical valve (excl. motor/pump) | 300 | 1970x1040x1170 | |||||
1.249.110 | 2-D MPU-M with pneumatic valve (excl. motor/pump) | 300 | 1970x1040x1170 | |||||
1.249.120 | 3-D MPU-M with mechanical valve (excl. motor/pump) | 300 | 1970x1040x1170 | |||||
1.249.125 | 3-D MPU-M with pneumatic valve (excl. motor/pump) | 300 | 1970x1040x1170 | |||||
1.249.130 | 4-D MPU-M with mechanical valve (excl. motor/pump) | 300 | 1970x1040x1170 | |||||
1.249.135 | 4-D MPU-M with pneumatic valve (excl. motor/pump) | 300 | 1970x1040x1170 |